FCM50-Thermal Gas Mass Flowmeter

The thermal mass flowmeter adopts the principle of thermal diffusion, which is a technology with excellent performance and high reliability under harsh conditions. Typical sensing elements include two thermal resistors (platinum RTD), a speed sensor and a temperature sensor that automatically compensates for changes in gas temperature. When the two RTDS are placed in a medium, where the velocity sensor is heated to a constant temperature above the ambient temperature, the other temperature sensor is used to sense the medium temperature. The mass flow of gas through the velocity sensor is calculated by the heat transfer of the sensing element. As the gas velocity increases, the heat carried away by the medium increases. The temperature of the sensor decreases accordingly. In order to maintain a constant temperature, the working current through the sensor must be increased, and this increased portion of the current is not proportional to the velocity of the medium.
Applications

Air/gas/natural gas measurement

Water treatment

Petrochemical industry

Power plant

Metallurgical industry

Oil/Gas industry

Introduction

  1. Tube Diameter:DN10...DN300

  2. Simple installation and easy operation

  3. No temperature and pressure compensation

  4. No moving parts

  5. Range ratio wide, high precision, high reliability

  6. Low pressure loss

Technical

Specification Table

Order No

The inside diameter of DNDN10…DN300
Measuring mediumAir, natural gas, hydrogen, oxygen, chlorine, nitrogen, argon, ammonia, biogas, coal gas, phosgene, flue gas, etc.
Measuring range0.4...100m/s
Precision1class,1.5level (under reference conditions, refer to important parameters for detailed explanation)
Repeatability±0.25%Measurements
Operating Voltage220VAC±10%;24VDC±10%
Output signalCurrent:4…20mA, HART, RS485pulse :frequency0-1KHZ
Work pressureDN10—DN50:≤4.0Mpa DN65—DN200:≤1.6MpaDN250—DN300:≤1.0Mpa
Sensor material316SS (1.4404),ceramics
Junction box shell materialCast aluminum
Flange,caseMaterialCarbon steel, stainless steel (customized)
Response time<100ms
Sensitivity<0.05m/s
Medium temperature-20°C...120°C, -20°C...250°C
Ambient temperatureSensor-25℃~60℃;
Environment humidity≤85%RH(20°Chour)
Power consumptionLess than20W
Structure typeOne-piece, two-piece
Electrical InterfaceM20×1.5
Grounding methodPipe grounding
Explosion-proof levelEXdIICT2...6
Connection methodFlange connection (according to internationalGB9115-88)
Degree of protectionIP65
Product order No.Measuring range
Nm3 /h
Pipe diameter
DN
Pressure
Mpa
 
FC00100.12…17104 
FC00150.3…4015↓↓↓ 
FC00200.5…7020  
FC00250.7…10025  
FC00321.2…17032  
FC00402…27040  
FC00503…42050  
FC00655…720651.6 
FC00808…110080↓↓↓ 
FC010012…1700100  
FC012520…2600125  
FC015030…3800150  
FC020050…6800200  
FC0250100…100002501 
FC0300150…150003001 
Integral structure    
Product order No.Measuring range
Nm3 /h
Pipe diameter
DN
Pressure
Mpa
 
FC10100.12…17104 
FC10150.3…4015↓↓↓ 
FC10200.5…7020  
FC10250.7…10025  
FC10321.2…17032  
FC10402…27040  
FC10503…42050  
FC10655…720651.6 
FC10808…110080↓↓↓ 
FC110012…1700100  
FC112520…2600125  
FC115030…3800150  
FC120050…6800200  
FC1250100…100002501 
FC1300150…150003001 
Separate structure    

Download

Application